Code: 017-0003-05
Description: ETB HP error
Causes: Engagement of the ETB was not completed at initialization.
Remedy: [Related parts] - Harnesses from the Duplex Driver PCB to the ETB Disengage Sensor 1. Duplex Driver PCB (UN80/J343) to Relay Connector (8P) (Unit of replacement: CABLE, FIXING/ FEEDER DRAWER) 2. Relay Connector (8P) to ETB Disengage Sensor (PS56/J2101) (Unit of replacement: SOLENOID ASSEMBLY) - Harness between the Duplex Driver PCB (UN80/J331) and the Duplex Feed Left Motor (M19/ J2111) (Unit of replacement: CABLE, MOTOR) - Harness between the DC Controller PCB (UN01/J431, J9, J432 and J8) and the Fixing Feed Drawer Unit (J5005) (Unit of replacement: CABLE, SIGNAL) - Harness between the Duplex Driver PCB (UN80/J300 and J301) and the Fixing Feed Drawer Unit (J5005) (Unit of replacement: CABLE, FIXING/FEEDER DRAWER) - ETB Disengage Sensor (PS56) - Duplex Feed Left Motor (M19) - Duplex Driver PCB (UN80) (Unit of replacement: DUPLEXING DRIVER PCB ASSEMBLY) - DC Controller PCB (UN01) (Unit of replacement: DC CONTROLLER PCB ASS'Y) [Remedy] - Check the ETB Disengagement Member (Transfer Frame Stopper). If it is left unremoved, remove it. - Check/replace the related harness/cable, connector and parts. [Reference] - To remove the ETB Disengagement Member, refer to the troubleshooting "Remedy to be implemented when the ETB Disengagement Member (Transfer Frame Stopper) is left unremoved" in the Service Manual. - Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES