Mã lỗi 881-0001-00 — Canon iR Advance 6575

Code: 881-0001-00

Description: Board over heat error
Causes: Abnormal temperature of the Main Controller CPU was detected.
Remedy: [Related parts] - Main Controller PCB 1 (PWB01) (Unit of replacement: MAIN CONTROLLER PCB ASS'Y, 1) - Main Controller PCB 2 (PWB02) (Unit of replacement: MAIN CONTROLLER PCB ASS'Y, 2) [Remedy] Perform the following in the order while checking whether the error is cleared. a. If the error occurred during a service visit and then occurred again: 1. Replace the Main Controller PCB 1. 2. Replace the Main Controller PCB 2. [CAUTION] When replacing the Main Controller PCB 2, execute "Adjustment after the Main Controller PCB 2 replacement" in situation mode. b. If the error does not occur during a service visit but is found in the log: 1. Clean the inlet on the side where the fan is installed and remove dust. 2. Remove dust from the fan in the Controller Box. 3. If the space on the side where the fan is installed is less than 10 cm, ask the customer to secure enough space.