Code: 053-0001-05
Description: Error in Reverse Upper Flapper Solenoid connection detection
Causes: Connection of the Reverse Upper Flapper Solenoid cannot be detected 5 times with 20 msec time interval.
Remedy: [Related parts] - Harness between the Duplex (UN80/J340) and the Reverse Upper Flapper Solenoid (SL05/ J2115) (Unit of replacement: CABLE, FIXING/FEEDER DRAWER) - Harness between the Duplex Driver PCB (UN80/J300, J301 and J310) and the Fixing Feed Drawer Unit (J5005) (Unit of replacement: CABLE, FIXING/FEEDER DRAWER) - Harness between the DC Controller PCB (UN01/J431, J9, J432 and J8) and the Fixing Feed Drawer Unit (J5005) (Unit of replacement: CABLE, SIGNAL) - Harness between the Main Driver PCB (UN78/J108) and the Relay PCB (UN86/J522) (Unit of replacement: CABLE, SIGNAL) - Harness between the Relay PCB (UN86/J517) and the Fixing Feed Drawer Unit (J5005) (Unit of replacement: CABLE, FIXING/FEEDER DRAWER) - Reverse Upper Flapper Solenoid (Unit of replacement: REVERSE SOLENOID ASS'Y) - Duplex Driver PCB (UN80) (Unit of replacement: DUPLEXING DRIVER PCB ASSEMBLY) - Relay PCB (UN86) (Unit of replacement: RELAY PCB ASSEMBLY) - Main Driver PCB (UN78) (Unit of replacement: MAIN DRIVE DRIVER PCB ASS'Y) - DC Controller PCB (UN01) (Unit of replacement: DC CONTROLLER PCB ASS'Y) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES