Code: E061-0101
Description: Potential control error (VD). Potential in the dark area did not fall within the range (target value +/-10V) although retry was executed 8 times at VD potential control.
Remedy: 1. Check the connection of the Pre-exposure LED (connector connection, open circuit, the caught cable). 2. If the current value of the Primary Charging Roller (COPIER > DISPLAY > DPOT > PRIM-C) is 1550 micro A or higher, execute 2-1 to 3. 2-1. Increase the grid voltage of the Primary Charging Assembly by 100V (COPIER > ADJUST > HV-PRI > PRI-GRID). 2-2. Execute the potential control (COPIER > FUNCTION > DPC > DPC). 2-3. Turn OFF and then ON the power. 3. Check the installation of the Primary Charging Assembly (connector connection, open circuit, the caught cable). 4. Check the installation of the Primary Charging High Voltage PCB (PCB11), and its connection (connector connection, open circuit, the caught cable). 5. Check the installation of the Drum Motor (M1), and its connection (connector connection, open circuit, the caught cable). 6. Replace the parts. Primary Charging Assembly Primary Charging High Voltage PCB Drum Motor (M1) Main Driver PCB (PCB2) DC Controller PCB (PCB1)