Code: E196-0002
Description: E2PROM data retrieval timeout
Within 10 sec since the power was turned ON, the E2PROM data cannot be developed to RAM
Within 10 sec since the power was turned ON, the E2PROM data cannot be developed to RAM
Remedy: EEPROM communication error in the DCON or the Drum Unit 1. Check the harness/connector between the DC Controller PCB (UN09/J25) and the Drum Unit Relay PCB (UN26/4011, UN27/J4014, UN28/J4017, UN29/J4020) 2. Check the contact surface on the Drum Unit Relay PCB and the Drum Unit Memory PCB (soil, damage, contact pressure) Y:UN26/UN30 M:UN27/UN31 C:UN28/UN32 Bk UN29/UN33 3. From Y Drum Unit, install each Drum Unit accordingly at a time to identify error ROM 4. Replace the DC Controller PCB (UN09)