Code: E003-0003
Description: Thermistor open circuit detection
In the period from initial rotation to printing, Sub Thermistor 1 detected a temperature of 40 deg C or lower for more than 3 seconds.
In the period from initial rotation to printing, Sub Thermistor 1 detected a temperature of 40 deg C or lower for more than 3 seconds.
Remedy: Fixing Assembly error, Fixing temperature detection error 1. Check failure between the DC Controller PCB (UN09/ J12) and the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable, open circuit, connector disconnection). -> Replace the part in the case of trapped cable/open circuit 2. Replace the Fixing Assembly 3. Replace the DC Controller PCB (UN09) NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR