Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E001-0002 — Canon iR Advance C2030L

Code: E001-0002

Description: Center Thermistor high temperature detection
Main Thermistor 1 detected a temperature of 283 deg C or higher for 0.1 sec or longer.
Remedy: Fixing Assembly error, Fixing temperature detection error 1. Check failure between the DC Controller PCB (UN09/ J12) and the Fixing Assembly (UN37/ J123, UN13/ J13) (trapped cable, open circuit, connector disconnection). -> Replace the part in the case of trapped cable/open circuit 2. Disconnect the connector of DC Controller PCB (UN09/ J12) and start the host machine to check the reading value of the following: service mode > COPIER > DISPLAY > ANALOG > FIX-E => When the value is 40 deg C or higher 3-1. Replace the DC Controller PCB (UN09) => When the value is lower than 40 deg C 3-2. Replace the Fixing Assembly NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR

← Xem tất cả mã lỗi Canon iR Advance C2030L

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie