Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E065-0002 — Canon iR Advance C2225

Code: E065-0002

Description: Error in detection of abnormal C charging AC current value
During the paper interval simple discharge current control, a current value that is higher than the target of 500[uA] is detected
Remedy: Error in output of charging high voltage, Drum Unit error or environment control error 1. COPIER > DISPLAY > ANALOG; check if the TEMP value and the HUM value are matched with the environment temperature. When the values are dramatically mismatched (Lager than 15degrees Celsius) 2-1. Check the harness and connector between the DC Controller (UN09/ J206) and the Environment Sensor (UN45) 3-1. Replace the Environment Sensor (UN45) 4-1. Replace the DC Controller (UN9) When the values are matched 2-2. Check the state of the charging high voltage contact point 3-2. Replace the Drum Unit (C) 4-2. Check the harness and connector between the DC Controller PCB (UN09/ J21) and the Primary Charging High Voltage PCB (UN06/ J441, J442) 5-2. Replace the Primary Charging High Voltage PCB (UN06) 6-2. Replace the DC Controller PCB (UN09)

← Xem tất cả mã lỗi Canon iR Advance C2225

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin