Code: E194-0000
Description: Registration detection error
When the number of reading patterns fails to be the specified value
When the number of reading patterns fails to be the specified value
Remedy: The patch by the registration detection is not correctly created, or registration patch sensor error 1. Clean the dustproof glass. 2. Check density on the image visually. When the image density is light 3-1. Clean the high voltage contact point with dry wiping or air blower. 4-1. Replace the Drum Unit (If the color showing abnormality can be identified from the image, replace the Drum Unit for that color. otherwise, replace from the Drum Unit (Y) in order) 5-1.Check the harness/connector between the DC Controller PCB (UN09) and the High Voltage PCB 6-1.Replace the High Voltage PCB. Primary Charging High Voltage PCB (UN06), Developing High Voltage PCB (UN07), Auxiliary High Voltage PCB (UN08), Primary Transfer High Voltage PCB (UN04) 7-1 Replace the DCON When the image density is not light 3-2. Use your hand to check that the shutter of the Registration Patch Sensor Unit can be open 4-2. Check for soil on the window of the Patch Sensor (UN43, UN44) 5-2.Check scar on the ITB. 6-2. Check movement of the Registration Shutter Solenoid COPIER > FUNCTION > PART-CHK > SL to move SL02 7-2.Check the harness/connector between the DC Controller PCB (UN09/J12) and the Patch Sensor (UN43/J4007, UN44/ J4006) 8-2. Replace the Registration Patch Sensor Unit 9-2 Replace the ITB Unit.