Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E720-0100 — Canon iR Advance C250

Code: E720-0100

Description: Cassette Pedestal detection error
Connection of the Cassette Pedestal could not be detected.
Remedy: [Related parts] - Cassette Pedestal - Harness between the DC Controller PCB (UN04/J190) and the drawer connector (J5904) on the host machine side (Unit of replacement: OPTION CST. DRAWER ASSEMBLY) - Harness between the drawer connector (J5950) on the Cassette Pedestal side and the Cassette Module Controller PCB (UN101/J650) (Unit of replacement: DRAWER CABLE ASSEMBLY) - Drawer on the host machine side (Unit of replacement: OPTION CST. DRAWER ASSEMBLY) - Drawer on the Cassette Pedestal side (Unit of replacement: DRAWER CABLE ASSEMBLY) - Cassette Module Controller PCB (UN101) (Unit of replacement: CST. PEDESTAL CONT. PCB ASS’Y) - DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/cable. [Remedy] Check/replace the related parts.

← Xem tất cả mã lỗi Canon iR Advance C250

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin