Description: Scanner communication error
DDI-S communication error (Vsync detection error)
Remedy: [Related parts] - Flexible Cable between the Scanner Unit (CIS01, CIS02/ J911) and the Main Controller PCB (UN81/J8101) (Unit of replacement: CABLE, FLAT) - Scanner Unit (CIS01/CIS02) (Unit of replacement: CONTACT IMAGE SENSOR ASSEMBLY) - Main Controller PCB (UN81) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/cable. [Remedy] Check/replace the related parts. After performing the remedy, check that the copy image is output normally.