Mã lỗi E002 0004 — Canon iR Advance C3325i

Code: E002 0004

Description: Fixing Main Thermistor temperature increase detection error. The Fixing Main Thermistor detected a temperature increase of 1 deg C for less than 5 sec from when the Fixing Heater was turned ON until start of PI control.
Remedy: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Thermistor 1. DC Controller PCB (UN04/J121) to Fixing Drawer (J1001DA) (Unit of replacement: FIXING DRAWER ASSEMBLY) 2. Fixing Drawer (J1001LA) to Relay Connector (8P) (Unit of replacement: CABLE, DRAWER RELAY) 3. Relay Connector (8P) to Fixing Thermistor (TH02) (Unit of replacement: FIXING FILM ASSEMBLY) • Harness between the DC Controller PCB (UN04/J115) and the Low Voltage Power Supply PCB (UN01/J322) (Unit of replacement: POWER SUPPLY ASSEMBLY) • Harness between the Low Voltage Power Supply PCB (UN01/J302) and the AC Interlock Switch (SW12) (Unit of replacement: CABLE, AC INTERLOCK SWITCH) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] 1. Check/replace the related harness/cable, connector and parts. 2. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

← Xem tất cả mã lỗi Canon iR Advance C3325i

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie