Mã lỗi E004 0002 — Canon iR Advance C3325i

Code: E004 0002

Description: Current detection circuit error. Current outside the specified range flowed to the Fixing Heater when the heater was turned ON. Or, failure of fixing current detection circuit was detected.
Remedy: [Related parts] • Harnesses from the Low Voltage Power Supply PCB to the Fixing Heater 1. Low Voltage Power Supply PCB (UN01/J302) to AC Interlock Switch (SW12) (Unit of replacement: CABLE, AC INTERLOCK SWITCH) 2. AC Interlock Switch (SW12) to Fixing Drawer (J1001) (Unit of replacement: FIXING DRAWER ASSEMBLY) 3. Fixing Drawer (J1001) to Relay Connector (3P) (Unit of replacement: CABLE, DRAWER RELAY) 4. Relay Connector (3P) to Fixing Heater (H1 and H2/J1115) (Unit of replacement: FIXING FILM ASSEMBLY) • Harness between the DC Controller PCB (UN04/J121) and the Fixing Drawer (J1001DB) (Unit of replacement: FIXING DRAWER ASSEMBLY) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

← Xem tất cả mã lỗi Canon iR Advance C3325i

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie