Description: Current detection circuit error. Current outside the specified range flowed to the Fixing Heater when the heater was turned ON. Or, failure of fixing current detection circuit was detected.
Remedy: [Related parts] • Harnesses from the Low Voltage Power Supply PCB to the Fixing Heater 1. Low Voltage Power Supply PCB (UN01/J302) to AC Interlock Switch (SW12) (Unit of replacement: CABLE, AC INTERLOCK SWITCH) 2. AC Interlock Switch (SW12) to Fixing Drawer (J1001) (Unit of replacement: FIXING DRAWER ASSEMBLY) 3. Fixing Drawer (J1001) to Relay Connector (3P) (Unit of replacement: CABLE, DRAWER RELAY) 4. Relay Connector (3P) to Fixing Heater (H1 and H2/J1115) (Unit of replacement: FIXING FILM ASSEMBLY) • Harness between the DC Controller PCB (UN04/J121) and the Fixing Drawer (J1001DB) (Unit of replacement: FIXING DRAWER ASSEMBLY) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES