Description: Fixing disengagement timeout error. The Fixing Pressure Release Sensor did not detect OFF status within 10 sec after the start of fixing disengagement operation.
Remedy: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Pressure Release Sensor 1. DC Controller PCB (UN04/J122) to Relay Connector (11P) (Unit of replacement: CABLE, FEED) 2. Relay Connector (11P) to Fixing Pressure Release Sensor (PS13) (Unit of replacement: PAPER DELIVERY DRIVE ASSEMBLY) • Harnesses from the DC Controller PCB to the Fixing Motor 1. DC Controller PCB (UN04/J122) to Relay Connector (8P) (Unit of replacement: CABLE, FEED) 2. Relay Connector (8P) to Fixing Motor (M09) (Unit of replacement: FIXING DRIVE MOTOR ASSEMBLY) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Fixing Pressure Release Sensor (PS13) • Fixing Drive Unit (Unit of replacement: FIXING DRIVE ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES