Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E020 03B8 — Canon iR Advance C3325i

Code: E020 03B8

Description: ATR Sensor (C) output error. The output value did not exceed 120 although the control voltage of the ATR Sensor (C) in the Developing Unit (C) was increased to 192 or higher, or it did not fall below 120 although the voltage was decreased to 42 at initialization.
Remedy: [Related parts] • Harnesses from the ATR Sensor (C) to the DC Controller PCB 1. ATR Sensor (C) (UN23/J1052) to Developing Unit (C) (J1042) (Unit of replacement: CABLE, DEVELOPING) 2. Developing Unit (C) (J1042) to Relay Connector (4P) (Unit of replacement: CABLE, RELAY) 3. Relay Connector (4P) to DC Controller PCB (UN04/J128) (Unit of replacement: CABLE, SENSOR) • Developing Unit (C) (Unit of replacement: DEVELOPING ASSEMBLY, C) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

← Xem tất cả mã lỗi Canon iR Advance C3325i

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie