Code: E025 0310
Description: Bottle Motor error (C). The Toner Supply Sensor (C) did not detect change for 1 sec or longer while the Bottle Motor (CK) was rotated at toner supply.
Remedy: [Related parts] • Harnesses from the Bottle Motor (CK) to the DC Controller PCB 1. Bottle Motor (CK) (M05) to Relay Connector (2P) (Unit of replacement: CABLE, BOTTLE DRIVE MOTOR) 2. Relay Connector (2P) to DC Controller PCB (UN04/J127) (Unit of replacement: CABLE, TONER BOTTLE) • Harness between the Toner Supply Sensor (C) (PS28/J1061) and the DC Controller PCB (UN04/J127) (Unit of replacement: CABLE, TONER BOTTLE) • Toner Supply Sensor (C) • Bottle Drive Unit (CK) (Unit of replacement: BOTTLE DRIVE ASSEMBLY, C, K) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES