Mã lỗi E073 0001 — Canon iR Advance C3325i

Code: E073 0001

Description: Interlock error. The Interlock (24 V) was not detected although all the doors of the host machine were closed.
Remedy: [Related parts] • Harnesses from the Interlock Switch 1 and 2 to the DC Controller PCB 1. Interlock Switch 1 and 2 (SW02 and SW03) to Relay Connector (9P) (Unit of replacement: CABLE, INTERLOCK SWITCH) 2. Relay Connector (9P) to DC Controller PCB (UN04/J133) (Unit of replacement: CABLE, SENSOR) • Harness between the Low Voltage Power Supply PCB (UN01/ J315 and J322) and the DC Controller PCB (UN04/J100 and J115) (Unit of replacement: POWER SUPPLY ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES