Description: ITB HP time out error. The HP Sensor in the Main Drive Unit did not detect home position within the specified period of time.
Remedy: [Related parts] • Harnesses from the DC Controller PCB to the Primary Transfer Roller Disengagement HP Sensor 1. DC Controller PCB (UN04/J131) to Relay Connector (3P) (Unit of replacement: CABLE, MAIN DRIVE) 2. Relay Connector (3P) to Primary Transfer Roller Disengagement HP Sensor (PS33/J1189) (Unit of replacement: CABLE, SENSOR) • Harness between the DC Controller PCB (UN04/J131) and the Primary Transfer Roller Disengagement Motor (M08/J1201) (Unit of replacement: CABLE, MAIN DRIVE) • Harness between the DC Controller PCB (UN04/J129) and the Bk Drum_ITB Motor (M02/J1054) (Unit of replacement: CABLE, MAIN DRIVE) • Primary Transfer Roller Disengagement HP Sensor (PS33) • Primary Transfer Roller Disengagement Motor (M08) • Bk Drum_ITB Motor (M02) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY) • ITB Unit (Unit of replacement: INTER. TRANSFER BELT ASS'Y) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES