Description: Serial communication error. Communication between the DC Controller PCB and the Laser Driver PCB was not completed.
Remedy: [Related parts] • Harness between the DC Controller PCB (UN04/J111) and the Y/M Laser Driver PCB (UN08/J202) (Unit of replacement: CABLE, CASSETTE SIZE) • Flat Cable between the Y/M Laser Driver PCB (UN08/ J203) and the C/Bk Laser Driver PCB (UN09/J801) (Unit of replacement: CABLE, FLAT) • Y/M Laser Driver PCB (UN08) (Unit of replacement: LASER SCANNER ASSEMBLY) • C/Bk Laser Driver PCB (UN09) (Unit of replacement: LASER SCANNER ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] 1. Check/replace the related harness/cable, connector and parts. 2. After replacement of the Laser Driver PCB, execute "Settings/ Registration> Adjustment/Maintenance> Adjust Image Quality> Auto Correct Color Mismatch". [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES