Mã lỗi E890 0001 — Canon iR Advance C3325i

Code: E890 0001

Description: Temperature detection error. The Environment Sensor did not detect change in temperature.
Remedy: [Related parts] • Harnesses from the DC Controller PCB to the Environment Sensor Unit 1. DC Controller PCB (UN04/J133) to Relay Connector (9P) (Unit of replacement: CABLE, SENSOR) 2. Relay Connector (9P) to Environment Sensor Unit (UN27/ J1107) (Unit of replacement: CABLE, INTERLOCK SWITCH) • Environment Sensor Unit (UN27) (Unit of replacement: ENVIRONMENT SENSOR ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES