Code: E014 0003
Description: Fixing Motor error. There was no FG signal input for 0.3 sec from the startup of the Fixing Motor.
Remedy: [Related parts] • Harnesses from the DC Controller PCB to the Fixing Motor 1. DC Controller PCB (UN04/J122) to Relay Connector (8P) (Unit of replacement: CABLE, FEED) 2. Relay Connector (8P) to Fixing Motor (M09/J1019) (Unit of replacement: FIXING DRIVE ASSEMBLY) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • Gears in the Fixing Unit 1. Cam Gear (Unit of replacement: CAM/GEAR, 3T/21T) 2. Pressure Roller Gear (Unit of replacement: GEAR, 36T) • Fixing Motor (M09) (Unit of replacement: FIXING DRIVE MOTOR ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check that the Fixing Unit is pushed into the host machine so the handle is locked. 2. Remove the Fixing Unit, and rotate the Cam Gear and the Pressure Roller Gear by hand to visually check that there is no bent or missing teeth or abnormal abrasion (edge of the gear is no longer tooth-shaped). 3. Replace the Fixing Unit. 4. Check the harness between the DC Controller PCB and the Fixing Motor. 5. Measure the both ends of the fuse in the Low Voltage Power Supply PCB using a tester. a. If the measurement value is less than 1 ohm (conduction state), 1. Replace the Fixing Motor. 2. Replace the DC Controller PCB. b. If the measurement value is 1 ohm or higher (non conduction state), replace the Low Voltage Power Supply PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES