Description: Registration Patch Sensor (Rear) density error. The background regular reflection output of the Registration Patch Sensor Unit (Rear) did not fall within the range from 115 to 1000 at initialization of the Developing Unit
Remedy: [Related parts] • Harnesses from the Registration Patch Sensor Unit (Rear) to the DC Controller PCB 1. Registration Patch Sensor Unit (Rear) (UN25/J1066) to Relay Connector (16P) (Unit of replacement: REGISTRATION SENSOR ASSEMBLY) 2. Relay Connector (16P) to DC Controller PCB (UN04/J120) (Unit of replacement: NEW OLD SENSING HOLDER UNIT) • Registration Patch Sensor Unit (Rear) (Unit of replacement: REGISTRATION SENSOR ASSEMBLY) • DC Controller PCB (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check if the sensor window of the Registration Patch Sensor Unit (Rear) is soiled. If it is soiled, clean it with lint-free paper moistened with water. 2. Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES