Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E196 0101 — Canon iR Advance C3330i

Code: E196 0101

Description: Communication error. Although access to the SCNR EEPROM from the DC Controller PCB (CPU) was performed 3 times, no response was received and timeout occurred.
Remedy: [Related parts] • Harness between the DC Controller PCB (UN04/J111) and the Y/M Laser Driver PCB (UN08/J202) (Unit of replacement: CABLE, CASSETTE SIZE) • Harness between the DC Controller PCB (UN04/J114) and the Secondary Transfer High Voltage PCB (UN03/J501) (Unit of replacement: CABLE, 2ND TRNSFR. H.V. PCB) • Y/M Laser Driver PCB (UN08) (Unit of replacement: LASER SCANNER ASSEMBLY) • Secondary Transfer High Voltage PCB (UN03) (Unit of replacement: 2ND TRNSFR. H.V. PCB ASS'Y) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

← Xem tất cả mã lỗi Canon iR Advance C3330i