Description: Zero cross signal detection error. Error due to disconnection of the fixing loopback signal After the frequency of zero cross signal fell into the specified frequency band, the frequency between 43 Hz and 67 Hz could not be detected for 0.5 consecutive sec.
Remedy: [Related parts] • Harness between the DC Controller PCB (UN04/J115) and the Low Voltage Power Supply PCB (UN01/J322) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04/J121) to Fixing Drawer (J1001) (Unit of replacement: FIXING DRAWER ASSEMBLY) • Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES