Mã lỗi E811 0000 — Canon iR Advance C3330i

Code: E811 0000

Description: Fuse in the Fixing Fuse PCB blowout error. The fuse in the Fixing Fuse PCB was not blown out at power-on.
Remedy: [Related parts] • Fixing Fuse PCB (UN31) (Unit of replacement: FIXING FUSE PCB ASSEMBLY) • Fixing Unit (Unit of replacement: FIXING ASSEMBLY) • DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) • Harnesses from the DC Controller PCB to the Fixing Fuse PCB 1. DC Controller PCB (UN04/J121) to Fixing Drawer (J1001DB) (Unit of replacement: FIXING DRAWER ASSEMBLY) 2. Fixing Drawer (J1001LB) to Fixing Fuse PCB (Unit of replacement: CABLE, DRAWER RELAY) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. • Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP • Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES