Description: Error in toner density (M) at communication failure of the Drum Unit Memory PCB (M)
Communication between the DC Controller PCB and the Drum Unit Memory PCB (M) was not available, and the output value (SigR) of the ATR Sensor (M) did not fall within the range from 50 or higher to 800 or less for 2 consecutive times.
Remedy: [Related parts] - Harness between the DC Controller PCB (UN04/J160) and the Drum Unit Relay PCB (M) (UN09/J6002) (Unit of replacement: PROCESS CONTROL PCB ASS’Y) - Drum Unit (M) (Unit of replacement: DEVE_UNIT_M) [Points to note at work] - When checking the harness/cable or connector, perform the following work. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/ cable. - If the Drum Unit Memory PCB (M) is soiled, clean it with a blower. [Remedy] Check/replace the related parts.