Description: Error in self-diagnosis of the encryption module
An error was detected in self-diagnosis of the encryption library.
Remedy: [Related parts] Flash PCB (UN96) [Points to note at work] Reinstall the necessary application software and restore the backup data once the error is cleared. [Remedy] Perform the following in the order while checking whether the error is cleared. 1. After reinstalling the system software using SST or a USB memory, turn OFF and then ON the main power. 2. Obtain the necessary backup data by referring to the backup data list. 3. Enter safe mode using (2+8) startup, and execute [4] Clear/ Format> [2] Flash Format (Flash format) using a USB memory. 4. After replacing the Flash PCB, reinstall the system software using SST or a USB memory. [Reference] For backup and restoration, refer to the Service Manual “Adjustment> Main Controller System” and “Appendix> Backup Data List”.