Mã lỗi E806-0401 — Canon iR Advance C350i

Code: E806-0401

Description: Duplex Cooling Fan error
The Duplex Cooling Fan in the Right Cover rotated for more than the specified period of time after the stop of drive.
Remedy: [Related parts] - Harnesses from the DC Controller PCB to the Duplex Cooling Fan 1. DC Controller PCB (UN04/J122) to Relay Connector (17P) (Unit of replacement: 2ST TRANS. H.V. CONTACT ASS’Y) 2. Relay Connector (17P) to Relay Connector (3P) (Unit of replacement: CABLE, DOOR, RIGHT) 3. Relay Connector (3P) to Relay Connector (3P) (Unit of replacement: CABLE, DOOR FAN, RIGHT) 4. Relay Connector (3P) to Duplex Cooling Fan (FM04) - Duplex Cooling Fan (FM04) - DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/cable. [Remedy] Check/replace the related parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

← Xem tất cả mã lỗi Canon iR Advance C350i

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie