Code: E025-0210
Description: Bottle Motor (YM) error (M)
The Bottle Rotation Sensor (M) did not detect rotation for 5 times in a row although 1.5 sec (2 sec in the case of right before replacement of the Toner Container) has passed after the Bottle Motor (YM) was turned ON.
The Bottle Rotation Sensor (M) did not detect rotation for 5 times in a row although 1.5 sec (2 sec in the case of right before replacement of the Toner Container) has passed after the Bottle Motor (YM) was turned ON.
Remedy: [Related parts] - Toner Container (M) - Harness between the DC Controller PCB (UN04/J155) and the Bottle Motor (YM) (M09/J6301) (Unit of replacement: CABLE, MAIN) - Harnesses from the DC Controller PCB to the Bottle Rotation Sensor (M) 1. DC Controller PCB (UN04/J151) to Relay Connector (3P) (Unit of replacement: CABLE, MAIN) 2. Relay Connector (3P) to Bottle Rotation Sensor (M) (PS07/ J5302) (Unit of replacement: CABLE, BOTTLE SENSOR, M/K) - Bottle Rotation Sensor (M) (PS07) (Unit of replacement: PHOTO INTERRUPTER) - DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY) - Bottle Drive Unit (YM) (Unit of replacement: BOTTLE DRIVE ASSEMBLY) - Hopper Unit (M) (Unit of replacement: HOPPER ASSEMBLY) [Points to note at work] - Be sure to turn over the Door Lock Lever when removing the Bottle Drive Unit (YM) and rotating the drive section by hand. - When checking the harness/cable or connector, perform the following work. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/ cable. [Remedy] Check/replace the related parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES