Description: TPM error
A communication error has occurred between the Main Controller PCB and the TPM PCB at startup.
Remedy: [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Turn OFF and then ON the main power, and check whether the error is cleared. 2. After turning OFF the main power, replace the TPM PCB (UN82) (Unit of replacement: TPM PCB ASSEMBLY). 3. If the TPM key was backed up, restore the key. 3-1. Connect the USB memory which stores the TPM key. 3-2. Execute “Settings/Registration> Log In> Management Settings> Data Management> TPM Settings> Restore TPM Key”. [Caution] Ask the customer to enter “System Manager ID” and “Password” when logging in. 3-3. Enter the password set at backup operation. 3-4. When the restoration completion screen is displayed, click “OK”. Remove the USB memory, and turn OFF and then ON the main power.