Description: Power Supply Cooling Fan error
It was detected that the Power Supply Cooling Fan was locked.
Remedy: [Related parts] - Harness between the Low-voltage Power Supply PCB (UN01/ J323) and the Power Supply Cooling Fan (FM05/J5215) (Unit of replacement: CABLE, POWER SUPPLY) - Harness between the Low-voltage Power Supply PCB (UN01/ J321) and the Main Controller PCB (UN81/J7010) (Unit of replacement: CABLE, POWER SUPPLY) - Power Supply Cooling Fan (FM05) - Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY) - Main Controller PCB (UN81) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY) [Points to note at work] When checking the harness/cable or connector, perform the following work. 1. Disconnect and then connect the connector to check that there is no bent pin and cable disconnection. 2. Visually check that the harness is not caught or open circuit. 3. If there is any error, replace the corresponding harness/cable. [Remedy] Check/replace the related parts.