Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E004-0002-05 — Canon iR Advance C355i

Code: E004-0002-05

Description: Main Thermistor and Sub Thermistor (Rear) disconnection detection error
Causes: Connection could not be detected within 0.5 sec when power was supplied to the Fixing Heater.
Remedy: [Related parts] R1.00 - Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) - Fixing Assembly - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

← Xem tất cả mã lỗi Canon iR Advance C355i

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin