Code: E009-0001-05
Description: Fixing pressure timeout error
Causes: Signal of the Fixing Pressure Release Sensor could not be detected at pressure application operation of the Fixing Pressure Release Cam, and the operation was not completed within 4 sec from the start of counterclockwise rotation of the Fixing Motor.
Remedy: [Related parts] R1.01 - Harness between the DC Controller PCB (UN04/J134) and the Fixing Drawer (DR01/J5401) - Harness between the Fixing Drawer (DR01/J5401) and the Fixing Pressure Release Sensor (PS13/J5403) - Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) - Harness between the Low-voltage Power Supply PCB (UN01/J315 and J322) and the DC Controller PCB (UN04/J20 and J22) - Fixing Pressure Release Sensor (PS13) - Fixing Motor (M04) - Fixing Drive Unit - Fixing Assembly - Low Voltage Power Supply PCB (UN01) - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. If periodic sound has occurred, check/replace the Fixing Assembly, Low-voltage Power Supply PCB, DC Controller PCB, and related harness. 2. If the Delivery Roller is rotating without noise, or if noise of the gear teeth being improperly meshed has occurred, check/replace the Fixing Drive Unit. 3. If the Delivery Roller is not rotating, check/replace the Fixing Motor, Fixing Drive Unit, Lowvoltage Power Supply PCB, DC Controller PCB, and related harness. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES