Code: E009-0004-05
Description: Fixing disengagement retry error
Causes: Signal of the Fixing Pressure Release Sensor could not be detected at pressure release operation of the Fixing Pressure Release Cam, and the operation was not completed within 3 times from the start of counterclockwise rotation of the Fixing Motor.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J134) and the Fixing Drawer (DR01/J5401) - Harness between the Fixing Drawer (DR01/J5401) and the Fixing Pressure Release Sensor (PS13/J5403) - Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) - Fixing Pressure Release Sensor (PS13) - Fixing Motor (M04) - Fixing Drive Unit - Fixing Assembly - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. Be sure to preferentially check the Fixing Drive Unit. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES