Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E012-0003-05 — Canon iR Advance C355i

Code: E012-0003-05

Description: CL Drum Motor error
Causes: There was no FG signal input for 300 msec from the startup of the CL Drum Motor in the Main Drive Unit.
Remedy: [Related parts] R1.00 - Harness between the CL Drum Motor (M01/J5701) and the DC Controller PCB (UN04/J140) - Fuse in the Low-voltage Power Supply PCB (UN01/FU14) - CL Drum Motor (M01) - Main Drive Unit - Low-voltage Power Supply PCB (UN01) - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check whether the gears of the Main Drive Unit can be rotated by hand. a. If they cannot be rotated, replace the Main Drive Unit. b. If they can be rotated, check the harness between the CL Drum Motor and the DC Controller PCB. 2. Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester. a. If power is flowing to it (the measurement value is less than 1 ohm), 1. Replace the CL Drum Motor. 2. Replace the DC Controller PCB. b. If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Lowvoltage Power Supply PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

← Xem tất cả mã lỗi Canon iR Advance C355i

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie