Mã lỗi E001-0003 — Canon iR Advance C5035F

Code: E001-0003

Description: High temperature error detected by hardware
Hardware detects abnormal high temperature of the Thermistor (Main Thermistor 1: 264 deg C, Main Thermistor 2: 265 deg C, Sub Thermistor 1, 2: 280 deg C) for 400 msec consecutively.
Remedy: 1. If the detected temperature of the Thermistor is less than the abnormal high temperature specified for Thermistor, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR; and then turn OFF and then ON the power. If it’s at abnormally high temperature, do not turn on the power before replacing the Film Unit. 2. Replace the Film Unit. 3. Replace the Shutter Unit. 4. Go through the following to check drive of FM5 and FM6: COPIER > FUNCTION > PART-CHK > FAN; if the not working properly, replace the fan. 5. Replace the DC Controller PCB (UN1). NOTE: After performing the above remedy work, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR.