Mã lỗi E025-0110 — Canon iR Advance C5045F

Code: E025-0110

Description: Timeout error in detection of Y Toner Bottle Seal/Release Sensor
Failure in detection about the changes of ON => OFF => ON with the sensor when the cap of the Y Toner Container was sealed/released.
Remedy: 1. Use the attached tool to manually rotate the Main Drive Unit to check the operation. 2. If the Main Drive Unit side failed to rotate, check the drive (to see damage of the gear, etc.) If it’s results in NG, replace the Main Drive Unit. 3. If the Main Drive Unit side failed to rotate while the Drive rotates, turn the Set-on Hopper Unit to check the rotating operation. If it’s results in NG, replace the Set-on Hopper Unit. 4. If both the Main Drive Unit and the Set-on Hooper Unit rotates together once the Main Drive Unit is manually rotated while sealing/releasing of the container works properly, check the sensor harness (to see if the harness is caught, disconnected or physically removed). 5. Replace the sensor which has been checked in step 4. 6. (If the above measures do not solve the problem,) Replace the Drum Driver PCB (UN4). NOTE: When checking the operation after performing the remedy, go through the following to clear the error: COPIER>FUNCTION>CLEAR>ERR; then, turn OFF and then ON the power. After performing the remedy, perform the toner replacement operation (from toner removal to reset/recovery) from the Control Panel at least once, and check that the replacement operation can be performed normally.

← Xem tất cả mã lỗi Canon iR Advance C5045F

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie