Mã lỗi 004-0000-05 — Canon iR Advance C5560i

Code: 004-0000-05

Description: Fixing Thermistor disconnection detection error
Causes: Open circuit of the Fixing Thermistor or connector disconnection was detected.
Remedy: - Harnesses connecting the DC Controller PCB (UN1/J122), the Drawer Unit (J5012) and the Fixing Thermistors (TH1/J6492 and TH2/J6491) - Fixing Thermistors (TH1 and TH2) - Film Assembly - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check that the Fixing Assembly is properly installed. 2. Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES