Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 009-0000-05 — Canon iR Advance C5560i

Code: 009-0000-05

Description: Fixing pressure timeout error
Causes: The Fixing Pressure Sensor did not detect ON status within 5 sec after the start of pressure application operation for fixing.
Remedy: - Harness between the Feed/Drum Driver PCB (UN2/J215) and the Fixing Motor (M21/J6084) - Harness between the DC Controller PCB (UN1/J172 and J170) and the Feed/Drum Driver PCB (UN2/J203 and J202) - Feed/Drum Driver PCB (UN2) - Fixing Motor (M21) - Fixing Drive Assembly - DC Controller PCB (UN1) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Turn OFF and then ON the main power. 2. Check that the Fixing Assembly is properly installed. 3. Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

← Xem tất cả mã lỗi Canon iR Advance C5560i

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie