Code: E013-0001
Description: Waste toner feed screw lock detection error. When the waste toner pipe screw lock SW (SW10) detected the lock status for 500msec (100msec x 5 times) consecutively
Remedy: Pull out the waste toner bottle. If it is full of toner, go to Step 2. If the waste toner bottle is not full of toner, go to Step 1, 2, and 4. If the waste toner bottle is not full and the waste toner pipe is not clogged with toner, go to Step 3 and 4. 1. If the waste toner pipe is clogged with toner, remove the toner in the pipe. 2. Replace the waste toner full sensor and the waste toner bottle. Remove the toner clog in the waste toner pipe. 3. Replace the waste toner screw lock detection switch (SW10). 4. Replace the waste toner drive unit.