Code: E013-0002
Description: Waste toner full sensor offset adjustment error. The sensor sampling result is not within a specified range.
Remedy: If the waste toner bottle is full of toner (if toner is viewable at the height of the detection window), go to Step 1. If the waste toner bottle is not full of toner (if toner is not viewable at the height of the detection window) and the detection window is stained with toner, go to Step 2. If the toner bottle is new, go to Step 3 and 4. If toner is not viewable at the height of the detection window and the window is not stained with toner while the waste toner bottle is not new, go to Step 3 and 4. If no fault is found after checking mentioned above is performed and the connector of the waste toner full sensor (TS9) is inserted, go to Step 4. 1. Replace the waste toner bottle with new one. If new one is not available, remove toner in the waste toner bottle. 2. Replace the waste toner bottle with new one. If new one is not available, clean the detection window in the waste toner container. 3. Check the connection between the waste toner full sensor (TS9) and the DC controller interface PCB. (Connection of the connector, Shorting, Wire caught by parts) Sensor side: J7010, PCB side: J1261, J8149 4. Replace the waste toner full sensor (TS9).