Mã lỗi E000-0101 — Canon iR Advance C7065

Code: E000-0101

Description: Pressure belt temperature rise is insufficient at power ON. Pressure main thermistor (THM2) temperature does not reach 50 degrees Celsius within 250 seconds after startup of pressure belt temperature control.
Remedy: 1. Check if the detection temperature of the thermistor is risen in service mode. A. In case that either one of the thermistor detection temperature is risen A-1. Check the pressure belt main thermistor (to see if the thermistor is disconnected, the harness of the thermistor is disconnected, foreign substance is in the thermistor, failure of the thermistor) -> replace the main thermistor or the pressure stay A-2. Faulty drawer connector is a possible cause -> clean the drawer connector or replace the fixing assembly B. In case that neither of them are not risen B-1. Check the connection of the AC driver connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-2. Replace the AC driver unit B-3. Replace the DC controller PCB B-4. Replace the fixing unit