Code: E077-0001
Description: Secondary transfer external roller detachment/attachment error. The secondary transfer roller attachment/detachment HP sensor (PS22) cannot detect the home position within a specified period. Connection failure Damage to the sensor Damage to the motor Damage to the drive assembly
Remedy: 1. Check the connection between the secondary transfer roller attachment/detachment HP sensor (PS22) and the fixing feed driver (UN5). (Connector, Breaking (shorting)) Sensor side: J7214, J8102 PCB side: 1509 2. Check the connection between the fixing feed driver (UN5) and the DC controller interface PCB. (Connector, Shorting) Fixing feed driver: J1550 DC controller interface PCB: J1214 3. Check the connection between the secondary transfer roller detachment motor (M31) and the pickup feed driver PCB (UN4). (Connector, Breaking (shorting)) Motor side: J7003 DC controller interface side: 1409 4. Check the connection between the pickup feed driver PCB (UN4) and the DC controller interface PCB. (Connector, Breaking (shorting)) Pickup feed driver PCB: J1401 DC controller interface PCB (UN2): J1215 5. Check the installation condition of the detachment mechanism assemblies (cam, arm, secondary transfer external roller holder). Check the condition of the attachment/detachment cam mechanism assembly. 6. Replace the secondary transfer roller attachment/ detachment HP sensor (PS22). 7. Check the drive gear. => Replace the gear. 8. Replace the secondary transfer roller detachment motor (M31). 9. Replace the drive unit.