Code: E025-03C0
Description: Error in C Toner Insertion Inlet Cover Sensor (PS16). Unable to detect opening of the Toner Insertion Inlet Cover when removing the Toner Container
Remedy: Identify the cause of the error whether it is due to link mechanism to open the Toner Insertion Inlet Cover or problem at the Toner Insertion Inlet Cover Sensor side. 1. Perform the user mode (Adjustment/Maintenance> Replace Specified Toner) to check if the Toner Insertion Inlet Cover opens normally (damage, slide of shaft area, etc.). 2. Check if the Toner Insertion Inlet Cover Sensor is soiled and the installation of the sensor. 3. Check the service mode (COPIER> I/O> DC-CON> P051 bit2) to see that the output value of the Toner Insertion Inlet Cover Sensor is changed normally when opening/closing the Toner Insertion Inlet Cover. If it is normal, the value becomes 0 by driving the Hopper Unit with the Toner Container Removing Tool and opening the Toner Insertion Inlet Cover. When closing the Toner Insertion Inlet Cover by hand, it becomes 1. 3-1. When the Toner Insertion Inlet Cover is not opened although the Hopper Unit is driven, check the drive system from upstream (Hopper Unit -> link mechanism of Hopper Tray -> Toner Insertion Inlet Cover Unit). If it is damaged, replace the damaged part and then perform step 5 and later steps. 3-2. When the output value is not changed normally although the Toner Insertion Inlet Cover can be opened/closed, check the Sensor Harness (to see if the harness is caught, disconnected or physically removed, *including the Relay Connector). If there is no problem, replace the sensor. After checking the output value in step 3, perform step 5 and later steps. 4. If the problem is not solved by replacing the foregoing parts, replace the DC controller PCB and then perform step 5 and later steps. 5. Clear the error in service mode (COPIER> FUNCTION> CLEAR> ERR), and then turn OFF and then ON the main power. 6. Replace the toner (reinstall the removed Toner Container) at least once in user mode (Adjustment/ Maintenance> Replace Specified Toner), and check that toner replacement can be performed normally.