Mã lỗi E025-0420 — Canon iR Advance C7270i

Code: E025-0420

Description: Toner container/toner container inserting inlet phase (Bk) error. When the power was turned on, it was detected that the toner container cap was opened (the release holder shift cam phase sensor was protected against light) AND the toner container inserting inlet cover was opened (the toner container inserting inlet cover open/close sensor was transmissive).
Remedy: 1. Close the toner container inserting inlet cover and turn OFF/ON the power. 2. Check the connection between the toner container inserting inlet cover open/close sensor (PS7) and the DC controller PCB. (Connection of the connector, Shorting, Wire caught by parts) Sensor side: J7138, PCB side: J1246 3. Check the connection between the release holder shift cam phase sensor (PS84) and the DC controller PCB. (Connection of the connector, Shorting, Wire caught by parts) Sensor side: J7139, J8040 PCB side: J1248 4. Replace the toner container inserting inlet cover open/ close sensor