Mã lỗi E003-0001 — Canon iR Advance C7280i

Code: E003-0001

Description: Fixing Film abnormally low temperature. After standby, fixing main thermistor (THM1) detected less or equal to 110 degrees Celsius in succession for 1 second.
Remedy: 1. Check the rear louver. (If the rear of the machine is close to the wall, temperature of the power supply area may rise) 2. Check the detection temperature of the thermistor in service mode (COPIER> DISPLAY> ANALOG> FIXxx). A. In case that either one of the thermistor detection temperature is risen A-1. Check the fixing film unit (to see if the location of the thermistor is inappropriate or the thermistor failure) -> replace the fixing film unit A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing drawer cable B. In case that neither of them are not risen B-1. Check the connection of the fixing thermistor (to see if the connection of the drawer is faulty, the connector is physically removed or disconnected) -> replace the fixing film unit B-2. Check the connection of the IH power connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-3. Replace the IH power unit B-4. Replace the DC controller PCB NOTE: After performing the above remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR