Code: E012-0502
Description: A. ITB Drive Roller Speed Detection PCB 1 signal error B. ITB drive motor error. A. The signal is not detected for 80msec or more. B. Lock signal of ITB drive motor (M3) cannot be detected for the specified period of time after first detection • Connector disconnected, Breaking (Breaking (shorting)) • Drum (unit) Y/M/C/K not inserted • Peeling of the ITB cleaning blade • Encoder Y/M/C/K failure (This occurs in rare cases.)
Remedy: A: A-1. Check the connection of the ITB Drive Roller Speed Detection PCB 1 (UN16). Sensor side: J7318, J8047PCB side: J1242 A-2. Take out the ITB Drive Roller Speed Detection PCB 1 to clean. A-3. Replace the ITB Drive Roller Speed Detection PCB 1. A-4. Check if the Harness of the ITB Drive Roller Speed Detection PCB 1 is faulty. (Replace the Harness if it’s disconnected.) A-5. Replace the DC controller PCB. B: B-1. Check the connection between the ITB driver motor (M3) and the DC controller PCB. (Connection of the connector, Breaking (Breaking (shorting))) Motor side: J7518, J8050 PCB side: J1242 B-2. Check the connection of the ITB drive roller speed detection PCB 1/2 (UN16/17). (Connection of the connector, Breaking (Breaking (shorting))) Motor side: J7318, J7319, J8047, J8050 PCB side: J1242 B-3. Reinstall the 4 color drum units. (If the drum unit is not installed properly, more load is applied to ITB drive.) B-4. Replace the drum unit. (Drum drive may be overloaded due to peeling of the blade, etc.) There may be cause in each color. B-5. Replace the DC controller PCB. NOTE: In some rare cases, this error occurs when the encoder is not installed with the drum speed detection PCB or when dirt is applied to the sensor surface of the drum speed detection PCB.