Code: E020-0081
Description: ITB base light intensity lower limit error. When executing ITB base correction, the average value of P wave light intensity detected/calculated is less than 300.
Remedy: • When the value of COPIER> DISPLAY> DENS> P-LED-DA is large (153(D) or more) and the value of P-SENS-P is small, there is a high possibility that dirt is applied to the patch sensor. • This occurs only at a regular timing. When the value of COPIER> DISPLAY> DENS> DENS-S-x is small (2 digits), there is a high possibility that breaking occurred. 1. Clean the patch sensor (PS21). 2. Check the connection between the patch sensor and the Drum ITB driver PCB. (UN6. (Connector, Shorting) Sensor side: J7412, J8035 PCB side: J1907 3. Check open/close operation of the patch shutter. 4. Check whether scratches/dirt are applied to the ITB. If many scratches are found, replace the ITB. If dirt is applied, clean the ITB. In this case, check the ITB cleaning blade at the same time. 5. Replace the patch sensor unit.