Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E020-0134 — Canon iR Advance C7280i

Code: E020-0134

Description: Initial installation patch (Y) density upper limit error. When executing developing assembly initial installation mode (COPIER> FUNCTION> INSTALL> INISET-Y), the ATR patch output (SigD) is more than 970.
Remedy: • When the value of COPIER> DISPLAY> DENS> P-LED-DA is large (153(D) or more) and the value of P-SENS-P is small, there is a high possibility that dirt is applied to the patch sensor. • This occurs only at a regular timing. When the value of COPIER> DISPLAY> DENS> DENS-S-x is small (2 digits), there is a high possibility that breaking occurred. 1. Check whether the developing assembly and the drum unit are properly installed. 2. Clean the patch sensor (PS21). 3. Check the connection between the patch sensor and the Drum ITB driver PCB (UN6). (Connector, Shorting) Sensor side: J7412, J8035 PCB side: J1907 4. Check open/close operation of the patch shutter. 5. Clean or replace the ITB. • Check whether the ITB belt is dirty or not. If it is dirty, perform cleaning with the service mode (COPIER> FUNCTION> CLEANING> TBLTCLN). • If it is assumed that this error occurred due to scratches on the ITB, replace the ITB. 6. Replace the patch sensor unit. 7. Replace the developing assembly.

← Xem tất cả mã lỗi Canon iR Advance C7280i

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie