Code: E020-0191
Description: Patch (Y) density upper limit error. The ATR patch detection output (SigD) is more than 970.
Remedy: • When the value of COPIER> DISPLAY> DENS> P-LED-DA is large (153(D) or more) and the value of COPIER> DISPLAY > DENS >P-SENS-P is small, there is a high possibility that dirt is applied to the patch sensor. • This occurs only at a regular timing. When the value of COPIER> DISPLAY> DENS> DENS-S-x is small (2 digits), there is a high possibility that breaking occurred. 1. Check whether the developing assembly and the drum unit are properly installed. 2. Clean the patch sensor (PS21). 3. Check the connection between the patch sensor and the Drum ITB driver PCB (UN6). (Connector, Shorting) Sensor side: J7412, J8035 PCB side: J1907 4. Check open/close operation of the patch shutter. 5. Check whether scratches/dirt are applied to the ITB. If many scratches are found, replace the ITB. If dirt is applied, clean the ITB. In this case, check the ITB cleaning blade at the same time. 6. Replace the patch sensor unit. NOTE: This error also occurs when there is not enough toner in the developing assembly. In this case, check the supplyrelated parts in the developing assembly.